MODEL NO.               FY14630000
OUTPUT VOLTAGE    14.6V
OUTPUT CURRENT   30A
OUTPUT POWER      438W

Features
  • Universal AC input / Full range
  • Plastic or metal case optional
  • Cooling by free air convection
  • regulated output with low ripple noise
  • 4 hours full load aging test
  • Modified and customized design are accepted
  • Certification:UL,ETL,CUL,GS,CE,UKCA,SAA,KC,PSE,CB,FCC,EMC,RoHS,REACH
Price: $ 58
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Product Description


OUTPUTMODEL NO.FY1462000FY1463000FY1464000FY1465000FY1466000FY1468000FY14610000FY14630000
OUTPUT VOLTAGE14.6V14.6V14.6V14.6V14.6V14.6V14.6V14.6V
OUTPUT CURRENT2A3A4A5A6A8A10A30A
OUTPUT POWER29.2W43.8W58.4W73.0W87.6W116.8W146.0W438.0W
RIPPLE & NOISE (Max.)146mVp-p146mVp-p146mVp-p146mVp-p146mVp-p146mVp-p146mVp-p146mVp-p
INPUTVOLTAGE RANGE100-240VAC~50/60Hz
NO LOAD POWER  (Max.)0.5W Max.1.8W
LOADING POWER (Max.)33.6W50.3W67.1W83.9W99.5W132.7W164.0W481.3W
EFFICIENCY (Min.)87%87%87%87%88%88%89%91%
SIZEDIMENSION(MM)113*43.5*30113*43.5*30113*43.5*30133*58*31154*60*36154*60*36178*80*46338*112*178
PROTECTIONOVER CURRENT≦2.2A≦3.3A≦4.4A≦5.5A≦6.6A≦8.8A≦11.0A≦33.0A
SHORT CIRCUITCapable of withstanding continuous short circuit and recover automatically.
OVER VOLTAGEOutput voltage shall not exceed 15.9V under single component fails conditions.
OVER TEMPERATUREOnce the internal temperrature reach to 95℃, the output current will drop automatically.
REVERSE POLARITY[Optional] When the output polarity is reversed, the charger does not work and there is no output.
FULLY CHARGED SHUTDOWN[Optional] When the battery is fully charged (charger indicator light turns green), the charger will turn off automatically.
ANTI-SPARK[Optional] There is no spark generated when connecting the charger
SAFETY  & EMCSAFETY STANDARDSUL1012 & IEC 60335 & EN60335 & AS60335 & J60335 & KC60335
EMICISPR22 CLASS
PRODUCT RELIABILITYMTBF30000 hours for full rated load operation at 25 ℃
WARRANTY3 YEARS
TEMPERATURE RISING65 ℃ Max. at an ambient temperature of 25  ℃
DIELECTRIC WITHSTAND TEST5mA 300VAC for 1 minute between input and output, input and housing.
When choosing to increase the withstand voltage by 5%, the application time should be 3 seconds.
OPERATING AMBIENT TEMPERATURE RANGE-29℃ TO +35 ℃
STORAGE AMBIENT TEMPERATURE RANGE-40℃ TO +75 ℃
STORAGE HUMIDITY20% TO 65% RH
CONNECTORPLUG5521, 5525, RCA, XLR, XT60, M16, C14, etc./ Customized
CABLEUL2464 1M length / Customizable



Usage:

  1. Automotive Repair Industry: Used to charge the starter batteries of cars. In automotive repair shops, when the battery of a car is low, a charger is used to recharge the battery to ensure the car can start properly.

  2. Marine Industry: Used to charge the starter batteries of boats. Boats may need charging while docked to ensure the batteries can start the engine when needed.

  3. Emergency Power Systems: Used to charge backup power supply batteries. Backup power sources such as generators or solar systems often use lead-acid batteries, and a charger ensures they remain charged for emergency use.

  4. Electric Vehicle Industry: Used to charge the battery packs of electric vehicles. Battery packs of electric bikes, scooters, and other electric vehicles need regular charging to maintain performance and lifespan.

  5. Telecommunications Industry: Used to charge backup battery packs of communication base stations. Communication base stations are typically equipped with backup power sources to cope with power outages, and chargers ensure these backup power sources remain charged.

  6. Solar Energy Systems: Used to charge battery banks in solar energy storage systems. Battery banks in solar energy systems need regular charging to ensure the system operates reliably, especially during adverse weather conditions.

  7. Agricultural Machinery: Used to charge starter batteries of agricultural machinery. Tractors and other agricultural machinery on farms require regular charging of their starter batteries to ensure smooth operation.

  8. Industrial Equipment: Used to charge backup battery packs of industrial equipment. In factories or manufacturing environments, certain equipment may require backup power sources to cope with power outages or emergencies.

  9. Security Systems: Used to charge backup batteries of security cameras and devices. Security cameras and alarm systems often require backup power sources to ensure they remain operational during power outages.

  10. Emergency Rescue Equipment: Used to charge backup battery packs of medical equipment. Hospitals or emergency vehicles may rely on backup power sources for critical medical equipment to ensure continued operation during power outages.


These scenarios illustrate the importance of a 14.6V 30A Lead Acid Battery Charger across various industries and equipment, ensuring reliability and continuous performance of the devices.


Previous: 
Next: 
Sign up for the latest updates on Fuyuang products

Categories

Quick Links

Applications

Help

Copyright © 2023 Fuyuan Electronic Co., Ltd. All Rights Reserved. Sitemap | Supported by leadong.com.